Operating Instructions
Setting Up Serial Links
Serial links are set up through the Serial menu which provides options for selecting the type of data to
be transmitted and/or received and how the data is communicated. To enable communications over a
serial link to function, the detector must have as a minimum the additional serial link board with
cabling. Report options will require the further addition of an Ethernet module.
To set up a serial link, proceed as follows:
1.
Select Menus > Service > Serial to display the Serial menu options which are listed and
described below.
2.
Use the Navigation Keys
to select each option in turn press the OK /
Enter Key
to enable the value to be edited.
3.
Use the Navigation Keys
to select the required option value and then
press the OK / Enter Key
to confirm the selection.
4. Repeat step 2 and 3 until you have selected and confirmed values for each option.
The Serial menu options available are as follows:
Usage
Options are provided for selecting how the connection is going to be used. Four options are
available which are described below.
O
Not used
Select this option if you do not wish to use a serial connection.
O
Lomalink
Select this option if you wish to create a connection with the LomaLink application for
two-way communication and control.
LomaLink enables data to be requested from and sent to the metal detector, and enables
remote control of the metal detector.
O
Reports
Select this option if you wish to send Reports and Logs over the serial connection either
manually or automatically. See Logs and Reports for further details.
O Resultant
Select this option if you wish to send product resultant signals over the serial connection.
If a Product Registration Photo-eye is fitted then a signal is sent for each pack as it is
inspected. If a Product Registration Photo-eye is not fitted then the current signal is sent
over the connection about once a second.
The remaining menus determine the required serial connection protocol. Whichever
settings are chosen they must match those used by the equipment the detector is
communicating with.
Baud rate
Options for selecting the baud rate to be used for the connection are provided.