Auto-Clean™ Drain Cleaning Machine
wind up and control the cable. As you feel the cable
wind up or if the cable end stops turning, immediately re-
lease the advance feed and depress the retrieve feed
lever to free the cable end from the blockage. Don’t keep
the cable rotating if the cable end is stuck in a blockage.
If the cable end stops turning and the drum keeps rotating,
the cable can twist, kink or break.
Once the cable end is free of the blockage and the cable
end is turning again, you can slowly feed the rotating
cable end back into the blockage. Let the spinning cable
end “dwell” in the blockage to help completely break it up.
Do not try to force the cable end through the blockage.
Work the cable end in this manner until it has moved com-
pletely past the blockage (or blockages), and the drain is
flowing.
While working the blockage, the cable end may become
clogged with debris and cuttings from the blockage. This
can prevent further progress. The cable needs to be re-
trieved from the drain and the debris removed.
See
section on “Retrieving the Cable”.
If the cable end continues to get hung up in the blockage,
a different drain cleaner may need to be used.
Handling A Stuck Tool
If the cable end stops turning and the cable cannot be
pulled back from the blockage, release the foot switch,
maintain a firm grip on the AUTOFEED and guide hose
and release the feed lever. Do not remove your hand
from guide hose or the cable may kink, twist and
break. The motor will stop and the cable and drum will turn
backwards until the energy stored in the cable is relieved.
Do not remove hand from the AUTOFEED and guide
hose until the tension is released. Place ON/OFF/REV
switch in the OFF position.
Freeing A Stuck Tool
If the tool is stuck in the blockage, hold the ON/OFF/REV
switch in the REV position. With both AUTOFEED levers
released press the foot switch for several seconds until it
is free of the blockage. Do not operate the machine in the
REV position any longer than required to free the cable
end from the blockage or cable damage can occur. Place
the ON/OFF/REV switch in the ON position and con-
tinue cleaning the drain.
Retrieving The Cable
Once the drain is open, if possible start a flow of water
down the drain to flush the debris out of the line. This can
be done by turning on a faucet in the system or other
methods. Pay attention to the water level, as the drain
could plug again.
With water flowing through the drain, retrieve the cable
from the line by depressing the retrieve feed lever. The
ON/OFF/REV switch should be in the ON position – do
not retrieve the cable with the ON/OFF/REV in the REV
position, this can damage the cable. As with feeding the
cable into the drain, keep hands firmly on the AUTO-
FEED and guide hose for control. The cable end can
become caught while being retrieved. The flow of water
down the line will help to clean the cable as it is re-
trieved. Continue retrieving the cable until the tool is just
inside the drain opening. Release the feed lever and re-
lease the foot switch, allowing the cable to come to a
complete stop. Do not pull the end of the cable from the
drain while the cable is rotating. The tool can whip
around and could cause serious injury.
Place the ON/OFF/REV in the OFF position and with
dry hands unplug the machine. Pull the remaining cable
from the drain by hand and feed into the drain cleaner. If
needed, continue cleaning following the above process.
Several passes through a line are recommended for
complete cleaning.
Maintenance Instructions
WARNING
ON/OFF/REV switch should be OFF and machine un-
plugged before performing any maintenance.
Always wear safety glasses and leather work gloves
when performing any maintenance.
Cables
Cables should be thoroughly flushed with water after
every use to prevent damaging effects of sediment and
drain cleaning compounds. Flush cable with water and
drain debris from drum by tipping machine forward after
every use to remove sediment, etc. which can corrode
cable.
AUTOFEED
After each use, hose out AUTOFEED assembly with
water and lubricate with lightweight machine oil.
Cleaning
The machine should be cleaned as needed with hot,
soapy water and/or disinfectants. Do not allow water to
enter motor or other electrical components. Make sure
unit is completely dry before plugging in and using.
Replacing the Cable
1. Remove the guide hose by pulling it off of the nose of
the machine. Pull up on the AUTOFEED levers so that
the end of the cable can fit through the AUTOFEED
and pull the cable through the guide hose. Push re-
maining cable back into the drum until just the tip of the
cable is left outside of the nose of the machine.