E-Z Tec Analog Control (E-Z Tec V Only)
• The LED display will provide a visual
indication of the strength of the
detection signal in relation to the
metal size, and is also used to
monitor the phasing–out procedure
used for products that cause false
detection due to the presence of
moisture, salts or additives.
• Sensitivity control allows adjustment
of the detection threshold for
minimum and maximum metal
sensitivities.
• Phase provides the user with control
for adjusting the metal detector for
product effect.
• Travel Time is an adjustment for delay
of the detection signal output. This
will allow time for the detected
contaminant to be positioned at the
downstream reject device (such as, air
blow off, pusher bar, flip gate, etc.).
• Reject Time is a variable adjustment
for extending the reject output signal.
This feature allows the user to adjust
the reject output time from 0 to 10
seconds.
The E-Z Tec Analog Control utilizes a
unique combination of digital circuitry
and solid state amplifiers to process the
received signal. A crystal oscillator
provides a stable reference and drift free
electronics and provides the user with
manual selection of either WIDE ZONE
detection or NARROW ZONE detection.
• Wide Zone detection should only be
used where the incidence of static
discharge from product is contained
or antistatic pipes are used. Static
electricity is a unipolar discharge.
The polarity will either be positive or
negative causing a disturbance on at
least one of the two receiver coils. If
the disturbance is large enough a
false detection could occur.
• Narrow Zone detection will almost
eliminate false detections caused by
static electricity. Narrow Zone
requires each receiver coil to be
disturbed within a given time period,
and if only one coil is affected a
detection will not take place.
• Mechanical Relays include two
individual fused (5 amp) relays with
independent control for various
output functions (reject devices,
alarms, PLC’s, etc.).
SPECIFICATIONS
Power Supply
120V/240V, 48-62 Hz
Fuses
One for the electronic circuitry and one
for each solid state and mechanical relay.
Status Lamps
Yellow: fault
Red: detect
LED Bar Graph Display
Shows power–on status and metal
signal level.
Reject Timing
Variable delay and duration shift
register stores multiple detections for
precise rejection of tramp metal. Clock
pulse input provided for variable
product speeds.
Frequency
Optimized for aperture size and product
to be inspected.
Product Speed
3 fpm to 8000 fpm
(0.02mps to 40 mps)
Output Control
Two mechanical relays. AC or DC,
solid state relays available as an option.
Sensitivity
Detector provides 100 levels at which
metal will be detected.
Phase Control
Can be used to either peak the response
to a particular metal or to suppress the
response to the product under inspection
(1,000 settings available).